| 1 | smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build) |
|---|
| 2 | Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net |
|---|
| 3 | |
|---|
| 4 | === START OF INFORMATION SECTION === |
|---|
| 5 | Model Family: Fujitsu MHV series |
|---|
| 6 | Device Model: FUJITSU MHV2100AH |
|---|
| 7 | Serial Number: - |
|---|
| 8 | Firmware Version: 000000A0 |
|---|
| 9 | User Capacity: 100,030,242,816 bytes |
|---|
| 10 | Device is: In smartctl database [for details use: -P show] |
|---|
| 11 | ATA Version is: 7 |
|---|
| 12 | ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a |
|---|
| 13 | Local Time is: Tue May 22 10:20:59 2012 JST |
|---|
| 14 | SMART support is: Available - device has SMART capability. |
|---|
| 15 | SMART support is: Enabled |
|---|
| 16 | |
|---|
| 17 | === START OF READ SMART DATA SECTION === |
|---|
| 18 | SMART overall-health self-assessment test result: PASSED |
|---|
| 19 | |
|---|
| 20 | General SMART Values: |
|---|
| 21 | Offline data collection status: (0x00) Offline data collection activity |
|---|
| 22 | was never started. |
|---|
| 23 | Auto Offline Data Collection: Disabled. |
|---|
| 24 | Self-test execution status: ( 0) The previous self-test routine completed |
|---|
| 25 | without error or no self-test has ever |
|---|
| 26 | been run. |
|---|
| 27 | Total time to complete Offline |
|---|
| 28 | data collection: ( 544) seconds. |
|---|
| 29 | Offline data collection |
|---|
| 30 | capabilities: (0x7b) SMART execute Offline immediate. |
|---|
| 31 | Auto Offline data collection on/off support. |
|---|
| 32 | Suspend Offline collection upon new |
|---|
| 33 | command. |
|---|
| 34 | Offline surface scan supported. |
|---|
| 35 | Self-test supported. |
|---|
| 36 | Conveyance Self-test supported. |
|---|
| 37 | Selective Self-test supported. |
|---|
| 38 | SMART capabilities: (0x0003) Saves SMART data before entering |
|---|
| 39 | power-saving mode. |
|---|
| 40 | Supports SMART auto save timer. |
|---|
| 41 | Error logging capability: (0x01) Error logging supported. |
|---|
| 42 | No General Purpose Logging support. |
|---|
| 43 | Short self-test routine |
|---|
| 44 | recommended polling time: ( 2) minutes. |
|---|
| 45 | Extended self-test routine |
|---|
| 46 | recommended polling time: ( 69) minutes. |
|---|
| 47 | Conveyance self-test routine |
|---|
| 48 | recommended polling time: ( 2) minutes. |
|---|
| 49 | SCT capabilities: (0x003d) SCT Status supported. |
|---|
| 50 | SCT Error Recovery Control supported. |
|---|
| 51 | SCT Feature Control supported. |
|---|
| 52 | SCT Data Table supported. |
|---|
| 53 | |
|---|
| 54 | SMART Attributes Data Structure revision number: 16 |
|---|
| 55 | Vendor Specific SMART Attributes with Thresholds: |
|---|
| 56 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE |
|---|
| 57 | 1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail Always - 118381 |
|---|
| 58 | 2 Throughput_Performance 0x0004 100 100 000 Old_age Offline - 27721728 |
|---|
| 59 | 3 Spin_Up_Time 0x0003 100 100 025 Pre-fail Always - 1 |
|---|
| 60 | 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 368 |
|---|
| 61 | 5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail Always - 1 (1999, 1) |
|---|
| 62 | 7 Seek_Error_Rate 0x000e 100 100 000 Old_age Always - 786 |
|---|
| 63 | 8 Seek_Time_Performance 0x0004 100 100 000 Old_age Offline - 0 |
|---|
| 64 | 9 Power_On_Seconds 0x0032 095 095 000 Old_age Always - 2889h+07m+53s |
|---|
| 65 | 10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0 |
|---|
| 66 | 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 323 |
|---|
| 67 | 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 7 |
|---|
| 68 | 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 19395 |
|---|
| 69 | 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 26 (Lifetime Min/Max 8/57) |
|---|
| 70 | 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 81838 |
|---|
| 71 | 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 (1, 6966) |
|---|
| 72 | 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 |
|---|
| 73 | 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 |
|---|
| 74 | 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 |
|---|
| 75 | 200 Multi_Zone_Error_Rate 0x000e 100 100 000 Old_age Always - 17906 |
|---|
| 76 | 203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 3728140666352 |
|---|
| 77 | |
|---|
| 78 | SMART Error Log Version: 1 |
|---|
| 79 | No Errors Logged |
|---|
| 80 | |
|---|
| 81 | SMART Self-test log structure revision number 1 |
|---|
| 82 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error |
|---|
| 83 | # 1 Extended offline Completed without error 00% 2855 - |
|---|
| 84 | # 2 Short offline Completed without error 00% 2 - |
|---|
| 85 | # 3 Short captive Completed without error 00% 0 - |
|---|
| 86 | |
|---|
| 87 | SMART Selective self-test log data structure revision number 1 |
|---|
| 88 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS |
|---|
| 89 | 1 0 0 Not_testing |
|---|
| 90 | 2 0 0 Not_testing |
|---|
| 91 | 3 0 0 Not_testing |
|---|
| 92 | 4 0 0 Not_testing |
|---|
| 93 | 5 0 0 Not_testing |
|---|
| 94 | Selective self-test flags (0x0): |
|---|
| 95 | After scanning selected spans, do NOT read-scan remainder of disk. |
|---|
| 96 | If Selective self-test is pending on power-up, resume after 0 minute delay. |
|---|
| 97 | |
|---|